Allergen Free Almond Allergen Rapid Kit
RAPID 5 MINUTE ALMOND ALLERGEN RESULT

Features and Benefits
- Rapid Detection – results within 5 minutes after sample preparation
- Wide Application – food, CIP, and surface testing
- Time Saving – Single sample extraction for all rapid kits
- High Performance = High sensitivity with low detection limits
- Quantitative Results – Using strip readers (S-Flow Reader / 3PRMini)
- No False Negative – Built-in hook line to avoid false negatives
- Long shelf life (12 months)
- Room temperature storage
Intended Use
The ProGnosis Biotech Allergen Free Almond Test is a lateral flow immunoassay for the qualitative and quantitative detection of almond residues in food products, cleaning-in-place (CIP) solutions, and working surfaces. This test is designed for use by trained laboratory professionals in food safety and allergen management environments.
The kit provides a rapid and reliable screening method to support allergen control programs and compliance with labeling regulations, including EU Regulation (No. 1169/2011 Annex II) and similar frameworks in the USA, Canada, Australia, and New Zealand.
Principle of the Method
The Almond Free Test detects almond protein via specific antibodies immobilized on a nitrocellulose membrane. During testing, almond antigens in the sample react with antibodies conjugated to gold nanoparticles. The resulting immune complex migrates along the membrane, it reacts with gold-labeled antibodies forming visible lines:
- Test Line (T): Indicates presence of almond proteins.
- Control Line (C): Confirms test validity.
- Hook Line (H): Detects excessive antigen concentrations preventing false negatives.
For quantitative analysis, the test device can be read using the S-Flow Reader or 3PRMini system along with the corresponding software.
Hook Test and Its Significance
At high antigen concentrations, a ‘hook effect’ (prozone effect) may occur, resulting in a weak or absent Test Line. The Hook Line acts as an internal control to identify such conditions:
- Normal concentrations – Hook and Control Lines visible; Test Line intensity proportional to walnut protein concentration.
- High concentrations – Hook Line fades or disappears; Test Line may weaken or vanish.
- If both Hook and Test Lines are absent while Control Line remains visible, dilute the extract and repeat testing.
- This safeguard ensures accuracy and prevents false negatives even at high walnut protein levels.
One Sample Extraction – All Tests
Using a single sample extraction protocol across all Allergen Free Rapid kits delivers significant efficiency and consistency benefits. Laboratories and food production facilities can streamline workflows by preparing one extraction for multiple allergen tests, reducing hands-on time, minimising reagent use, and simplifying staff training. A unified extraction method also improves result reliability by ensuring that all allergens are tested from the same homogenised sample, reducing variability and the risk of sampling error. This approach supports faster turnaround, lower operational costs, and greater confidence in allergen monitoring across diverse product types.
Product Description
Format: Lateral Flow Cassette
Matrices: Beverages, Cake, Cereals, Chocolate, Cookies, Crackers, Ice Cream, Spices, and surface swabs
Test Time: 5 minutes
Calibration Range: 1–64 ppm (food) / 0.125–8 µg/100 cm² (surface)
Storage: 4–30°C
Shelf Life: 12 months
Method Characteristics
Limit of Detection (LOD): 0.5 ppm almond (0.105 ppm almond protein)
Limit of Quantification (LOQ): 1.0 ppm almond (0.21 ppm almond protein)
Surface LOD: 0.0625 µg/100 cm²
Surface LOQ: 0.125 µg/100 cm²
Test Time: 5 minutes (after sample extraction)
Reader Compatibility: S-Flow Reader / 3PRMini
Cross-reactivity
Minor cross-reactions may occur with cherry pit (Prunus avium). At high concentrations, cross-reactivity may appear with Lupin, Soya, Macadamia, Walnut, and Cashew.
Interpretation of Results
Negative: Hook and Control lines visible; no Test line.
Positive: Hook, Control, and Test lines visible; any Test line intensity indicates the presence of almond.
High Positive: Hook line absent; Test line faint or absent due to high antigen load.
Invalid: Control line absent; test invalid.
For quantitative measurement, insert cassette into the S-Flow Reader within 1 minute after reaction.
Limitations
• Negative results may indicate allergen levels below detection limit.
• Matrix effects may affect recovery.
• Highly processed foods may show reduced protein recovery due to denaturation.
Ordering Information
Stock Code Description Pack Size
PGB-E1010 ALMOND FREE ALLERGEN TEST 10
PGB-E1030 ALMOND FREE ALLERGEN TEST 30